[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]
Re: Limited number of flows for CBQ links?
>
> From: Marc Greis <[email protected]>
> To: [email protected]
> Subject: Limited number of flows for CBQ links?
> Date: Thu, 04 Jun 1998 11:51:22 +0200
>
> Hi,
>
> It seems like the flowid's for CBQ links can't be greater than 32. I
> can bind flows to a CBQ class (with $cbqlink bind $cbqclass <flowid>)
> with IDs of 1000 or higher without any problems, but when I send a flow
> with an ID that is higher than 32, I get a segmentation fault or an
> 'unknown-flow' error (depending on the total number of flows that I
> bind to a CBQ class, there also seems to be a limit for the total
> number of flows) . It would be very limiting for large-scale
> simulations to only be able to send 33 different flows. Is there a way
> to solve this problem or am I simply doing something wrong?
>
> Thanks,
>
> Marc
>
The 32 limit should only take effect in cases where you are using
nsv2 in v1 compatibility mode (there is a QueueMonitorCompat class which
has this limitation). Were you encountering this problem *not* in
compat mode?
- K